HX-1603PE
16+2+1-Port 100M PoE Switch
- Ports
- 16
- Budget
- 330W
Product category
Quick answer
A 16-port PoE switch powers 16 fixed domes (about 96 W) in one unit, or 6–10 PTZ heads, on a 200–330 W budget. All four models are 16+2+1: sixteen powered ports, two copper uplinks and one 1000Base-X SFP slot, so the run back to the core can leave the building on fibre.
Sixteen powered ports is a riser-closet or a mid-size site: a whole building on one unit, or a floor that is denser than eight ports allows. At this size the uplink becomes the design question — sixteen camera streams have to leave the box on one or two links.
The 4 models here run 200–330 W, in 100M and gigabit versions, with copper and SFP uplink combinations.
Every figure below comes from the current product data. Click a model to open its full specification page.
| Model | Uplink Ports | Power | Input | VLAN | Size (L×W×H) |
|---|---|---|---|---|---|
| HX-1603PE16+2+1-Port 100M PoE Switch | 2 × 10/100/1000Base-T(X) adaptive Ethernet ports 1 × 1000Base-X SFP fiber port | 330W | AC100-240V 50/60Hz | Yes | 310×180×44mm |
| HX-1603PEG16+2+1-Port Gigabit PoE Switch | 2 × 10/100/1000Base-T(X) adaptive Ethernet ports 1 × 1000Base-X SFP fiber port | 330W | AC100-240V 50/60Hz | Yes | 310×180×44mm |
| HX-X1603PE16+2+1-Port 100M PoE Switch | 2 × 10/100/1000Base-T(X) adaptive Ethernet ports 1 × 1000Base-X SFP fiber port | 200W | AC100-240V 50/60Hz | Yes | 310×180×45mm |
| HX-X1603PEG16+2+1-Port Gigabit PoE Switch | 2 × 10/100/1000Base-T(X) adaptive Ethernet ports 1 × 1000Base-X SFP fiber port | 200W | AC100-240V 50/60Hz | No | 310×180×45mm |
Calculated from the published budget of each model with a 20% reserve kept for PoE start-up surge, IR load at night and ageing. The figure is capped by the powered-port count, so it never promises more devices than there are ports. Budgets are pooled — one 25 W PTZ takes what several 6 W domes would.
| Model | PoE ports | Budget | Fixed dome6 W label | Wireless AP8 W label | 802.3af device15.4 W class | PTZ / 802.3at device25.4 W class |
|---|---|---|---|---|---|---|
| HX-X1603PE16+2+1-Port 100M PoE Switch | 16 | 200 W | 16 | 16 | 10 | 6 |
| HX-X1603PEG16+2+1-Port Gigabit PoE Switch | 16 | 200 W | 16 | 16 | 10 | 6 |
| HX-1603PE16+2+1-Port 100M PoE Switch | 16 | 330 W | 16 | 16 | 16 | 10 |
| HX-1603PEG16+2+1-Port Gigabit PoE Switch | 16 | 330 W | 16 | 16 | 16 | 10 |
Method: floor(budget × 0.8 ÷ device draw), capped at the powered-port count.Run your own numbers in the PoE budget calculator →
Up to sixteen, bounded by the 200–330 W budget. Sixteen domes at 6 W is 96 W and fits every model in this size; sixteen 802.3at devices at 15.4 W is 246 W, which the 330 W models cover and the 200 W models do not. The capacity table above gives the number per model.
These are unmanaged units: they forward tagged frames transparently and the panel switch isolates camera ports from the uplink, but there is no web interface, no SNMP and no configurable VLAN table. Where the site has an IT-managed core, an unmanaged edge is normally accepted for cameras as long as the core handles segmentation.
Access speed (100M or 10/100/1000Base-T), total budget (200 W or 330 W) and whether the VLAN isolation switch is fitted. The comparison table above lists all of it for every model in this size.
Yes. These are 16+2+1 units: sixteen powered ports, two copper uplinks and one SFP slot, all active at once. The copper uplinks are the usual path to a local NVR; the SFP slot is for the backhaul to the core or the next building.
It leaves four spare powered ports, which is the usual sizing rule for a site that may grow. Check the budget at the same time — twelve PTZ heads is about 300 W and needs the 330 W models rather than the 200 W ones.
Divide the budget by the number of powered ports to get an average, then check the worst case. On the 330 W model that average is about 20.6 W per port; on the 200 W model about 12.5 W. Neither is a per-port guarantee — two 25 W PTZs take what five domes would.
Not from the port itself — 100 m is the channel limit and PoE does not change it. Use a PoE extender mid-span (it re-powers the downstream segment) or place an 8-port switch nearer the cameras with an SFP uplink back to this unit.
22 models
Factory-direct PoE splitters — 22 models: 48 V PoE in, 12 V / 9 V / 5 V / 24 V out, standard and non…
View category7 models
Factory-direct 8-port PoE switches: 7 models, 100M and gigabit access, {budget} budget, 8+2 copper o…
View category4 models
Factory-direct 24-port PoE switches: 4 models, {budget} budgets, 100M and gigabit access, 24+2+2 or …
View category