HX-CH220V/10A: Auto-Reclosing Earth-Leakage Protector 220V 10A

HX-CH220V/10A Auto-Reclosing Earth-Leakage Protector 220V 10A — rated 145–280 V; In —; Imax 10 kA; housing 107×92×70 mm. Surge protection device supplied as an OEM/ODM build with custom branding and packaging on request.

HX-CH220V/10A

Specifications

Rated Voltage (Un)
145–280 V
Max Continuous Voltage (Uc)
280 V
Nominal Discharge Current (In)
—
Max Discharge Current (Imax)
10 kA
Size (L×W×H)
107×92×70 mm

OEM/ODM with custom branding, packaging and model numbers available. MOQ and pricing on request.

What is the HX-CH220V/10A protecting?

This unit guards the protected circuit. The specification gives a rated voltage of 145–280 V with a maximum continuous working voltage of 280 V — the highest steady voltage the component is designed to sit on without conducting.

Its housing is 107×92×70 mm, which is the number that decides whether it goes on a wall next to the camera, inside a cabinet, or on a DIN rail.

Every figure on this page matches the specification table above. For a tender, ask for the current datasheet before quoting.

What do In and Imax mean on this model?

Nominal discharge current (In) is — and maximum discharge current (Imax) is 10 kA. The two numbers are not interchangeable: In is the surge current the unit is expected to survive repeatedly over its service life, while Imax is the single-shot ceiling it can take once.

Both are quoted against the standard surge test waveform, an 8/20 µs current impulse. A real lightning strike on an outdoor camera line is not that waveform, which is why surge protection is specified by class and by installation point rather than by a single kA figure.

A protector is a sacrificial component: after a large event it may need replacing even though the equipment behind it survived. That is the design intent — a cheap replaceable part takes the hit instead of the camera or the switch.

Where does it go in the installation?

At the boundary. The protector belongs at the point where the line enters the building or leaves it — before the protected equipment, on the side facing the surge. Fitting it at the far end of a long run, next to the camera, leaves the whole run exposed upstream.

The earth connection is the part that actually does the work. A surge protector with a long, thin or shared earth lead raises the clamping voltage at the equipment by the voltage drop along that lead, and the protection is only as good as that path. Keep the earth lead short and direct, and bond it to the same earth as the equipment it protects.

The housing measures 107×92×70 mm, so plan the enclosure or rail space before ordering.

Which model in the range fits my site?

Start from the rail being protected — data pair, PoE line or AC supply — then from the exposed length and the exposure of the site. The table compares the family on the four rows that decide the choice.

ModelUnImaxRateSize
HX-1000EP-4/PW220 V10 kA10/100/1000 Mbps107×65×27 mm
HX-100EP-2/PW220 V10 kA10/100 Mbps107×65×27 mm
HX-100EPD-3/PW220 V10 kA10/100 Mbps107×65×27 mm
HX-DG20/2P220 V20 kA—94×65×36 mm
HX-DG20/4P380 V20 kA—94×65×72 mm
HX-DG200/2220 V10 kA10/100 Mbps96×66×36 mm
HX-DG2000/2220 V10 kA10/100/1000 Mbps96×66×36 mm
HX-DG2000/POE48 V5 kA10/100/1000 Mbps96×66×36 mm

FAQ

Does the HX-CH220V/10A protect PoE lines as well as data?

It protects the rail it is rated for: 145–280 V rated, 280 V continuous. A PoE line sits at 44–57 V, so a unit rated at 145–280 V is the one to compare against the voltage actually present on the line. Check the Rated Voltage row against the supply before ordering — a data-pair protector on a PoE line is the wrong component even though both use RJ45.

One protector per camera, or one per switch?

It depends on where the surge enters. One at the building entry protects everything behind it against the bulk of the energy; individual units at the camera end protect against surges induced on the last leg of the run, which a single entry-level device cannot clamp at the far end. Exposed outdoor runs are the case for per-camera protection.

Does it need a separate earth?

It needs a low-impedance path to the same earth as the protected equipment. A separate, isolated earth electrode creates a potential difference between the two ends of the cable, which is exactly the condition that damages network ports. Bond to the building earth, close to the protector.

Will it affect the link speed?

Transmission rate is not listed for this model because it protects the power side rather than the data pair.

How do I know when it has done its job?

Most of these units carry a status window or are replaced on schedule after a known event. If a site has had a direct strike nearby, replace the protector rather than waiting for a failure — a degraded protector still passes traffic and silently stops clamping.

Specifications for model HX-CH220V/10A. Ask for the current datasheet before quoting.