PoE Switches

HX-0802PE: 8+2-Port 100M PoE Switch

HX-0802PE 8+2-Port 100M PoE Switch — network side: 8 × 10/100Base-T(X) adaptive PoE Ethernet ports; uplink: 2 × 10/100Base-T(X) adaptive Ethernet ports; power budget 120W. It is supplied as an OEM/ODM build with custom branding and packaging on request.

HX-0802PE

Specifications

Network Ports
8 × 10/100Base-T(X) adaptive PoE Ethernet ports
Uplink Ports
2 × 10/100Base-T(X) adaptive Ethernet ports
VLAN
Yes
Input
AC100-240V 50/60Hz
Power
120W
Pinout
(1/2)+,(3/6)-
Size (L×W×H)
190×125×38mm

OEM/ODM with custom branding, packaging and model numbers available. MOQ and pricing on request.

What is the HX-0802PE used for?

The HX-0802PE sits at the head of the run: it terminates the camera links, carries the video back to the NVR and supplies DC power on the same cable pairs. In a typical IP camera installation it is the part that decides how many devices can be powered, how much headroom is left for future cameras, and whether a long cable run still needs a relay point.

As built: network side 8 × 10/100Base-T(X) adaptive PoE Ethernet ports; uplink 2 × 10/100Base-T(X) adaptive Ethernet ports; housing 190×125×38mm.

What does the budget look like on a real site?

Three common camera mixes, costed against the 120W budget. The last row is the worst case an installer has to check: every port loaded at the class limit. If it exceeds the budget the site will still work — until a cold night when heaters switch on.

The mix matters more than the average. A switch with a large budget and a small port count is a different product from one with the same total spread across 24 ports, even when the headline number is identical.

Camera mixLoadvs 120W
8 × fixed dome @ 6 W48 Wwithin budget
2 × PTZ @ 20 W40 Wwithin budget
8 × worst case @ 15.4 W123.2 Wover budget

How much PoE power does it deliver?

The rated PoE budget is 120W, shared across the 8 powered ports. Spread evenly that is about 15 W per port — an average, not a guarantee: PoE budgets are pooled, so two cameras drawing 25 W each will take more of the total than ten cameras drawing 5 W.

Size the budget with 20–30% headroom. Cameras with heaters, IR illuminators or PTZ motors draw their peak at night and in cold weather, exactly when the site is unattended.

How far can the link run?

Structured cabling limits a copper channel to 100 m between active devices. Switches and injectors terminate one segment; extenders exist to start a new one, so a run built from three segments can reach roughly 300 m — but every extra hop also re-supplies power from the same original budget.

How do I choose between the models in this range?

The siblings in this family differ on a small number of axes. Compare the powered port count first, then the budget, then the uplink — a model with SFP uplinks only pays off when the run back to the core is fibre.

ModelNamePorts · budget · class · speed
HX-0402PE4+2-Port 100M4 ports · 65W
HX-0403PEG4+2+1-Port Gigabit4 ports · 65W
HX-0803PE8+2+1-Port 100M8 ports · 120W
HX-0803PEG8+2+1-Port Gigabit8 ports · 120W

What should I confirm before ordering?

Five checks catch most of the mismatches we see on purchase orders for this family:

  • Port count against the camera count, with at least two spare ports — the 8 powered ports here are the hard ceiling.
  • Budget against the sum of device labels at their peak, not their average.
  • Uplink: copper is fine inside a building; SFP matters when the run back to the core is longer than 100 m — see the Uplink Ports row above.
  • PoE class of the cameras versus the PSE class — a mismatch only shows up at the powered device.
  • Mechanical: 190×125×38mm, and whether the enclosure is going on a wall, a DIN rail or a pole.

FAQ

How many cameras can the HX-0802PE power?

It depends on camera class, not on port count alone. With a 120W budget, eight 6 W fixed cameras and four 20 W PTZ units draw 128 W combined — within budget — while nine 25 W units would exceed it. Count the sum of the device labels, then keep 20–30% spare.

Does it do VLANs, or is it unmanaged?

The specification reads Yes. For a camera network the practical question is whether you need traffic separation between camera VLANs and the rest of the building — if the site has an IT department with a managed core, an unmanaged edge switch is usually accepted as long as it forwards tagged frames transparently.

What supply does it need?

Input is AC100-240V 50/60Hz. That is the unit's own supply, separate from the PoE it hands out on the ports; budget the circuit for the full rated load rather than the typical one.

Can it be supplied under our own brand?

Yes — we run OEM and private-label production on this range: custom branding, packaging and model numbers on the same hardware. Ask for the current datasheet and a sample plan before committing a project to a specific variant.

Where can I see the full specification?

Every figure in the specification table above comes from the current production data for this model. If a figure matters for a tender, ask for the current datasheet before quoting — printed documents and production revisions drift apart.

Specifications for model HX-0802PE. Ask for the current datasheet before quoting.

Chat with us on WhatsApp